DNA Fusion Version 7.0

RELEASE DATE(s): September 25, 2017- February 12, 2018

 
 

 

VERSION 7.0.2.24
RELEASE DATE February 12, 2018
MERCURY FIRMWARE 1.2.41 (SSP-D2, SSP-EP, SSP-LX, DController)
 

New Features

  • MiraSys Video Integration

Improvements

  • Added Card + Facility Code option to PCProx
  • Added thyssenkrupp Elevator Report
  • Added support for setting cardholder Use Counts via a Direct Command as well as a Macro action
  • Refactor DNA Driver Database mechanism now reduces the impact on the database during high volume situations
  • Added ability to output a native 200 Bit PIV format based on the PIV fields Open Options tracks
  • Fixed some display issues with the RSC-DT Firmware Dialog introduced with BCG 25
  • Changed minimum value downloaded for SSP Retry Timeout on Ethernet channels to 3000 from 700
  • Added ability to use NDE/PIM functionality on the D2 and 4502/LX. (this only works with firmware versions 1.25.6).
  • Various Driver Improvements: Allow bypass of auto card download on reset, better logging for discarded Mercury downloads, more logging around UTag Processing
  • Reworked logic around how tranTypeSys transactions are handled and improved logging
  • Reworked logic and improved logging in the handling of UTAGs
  • Changed the way the ‘Add Photo’ option from the Page ID screen works so that it functions with the same basic rules as ‘Take Photo’
  • Fixed trace history so report now obeys the “Access Only” events flag

Bug Fixes

  • Fixed issue where Subcontroller was added when not licensed for any subs
  • Fixed issue where when dragging an SSP to the events grid it was not showing all hardware related to that SSP
  • Fixed issue where supervised F2F Readers were reporting an offline event as a Fault: Shorted Loop instead of "Offline"
  • Fixed issue where when copying Trigger/Macros from one SSP to another could result in error message Destination SSP stored quantity amounts were exceeded
  • Fixed issue where Inovonics Points were not reporting specialized information (i.e. battery loss, etc.) in DNA Fusion
  • Fixed issue where when scanning for Exacq cameras, if you had the wrong server or an invalid username and password, the error being thrown is “Exacq Vision support files could not be found”
  • Fixed issue where Start, End Mode drop down list contains Otis Modes when it's not an Otis Door
  • Fixed issue where the drop down for the scheduled commands dialog lists ALL twice
  • Fixed issue where sites created by the driver seem to have the “Fully Qualified Name” checked but are not fully qualified, leading to error message in driver
  • Fixed issue where when copying objects on a graphics map, the tag assigned to the new objects occasionally matched objects already linked on the page
  • Fixed issue where Macro Action downloads to the scp_no parameter was hard coded to 0 (needed since 4.6.1.212 DLL started using that for regional I/O).
  • Fixed issue where when a person (or card) was removed, there was no audit record of the person being removed
  • Fixed issue where within Personnel Access Reports, only Global Groups or Individual Legacy Access Levels could be selected, not Legacy Groups
  • Fixed issue where TKE Audits could contain incorrect information
  • Fixed issue with thyssenkrupp - no rights checking on the Result Normal State
  • Fixed issue where Card Type and Reason were not saved properly when person had multiple cards
  • Fixed issue where user toolbars get duplicated everytime after reloading operator environment
  • Fixed issue where Channel defaults for SSP Retry timeout were incorrect for TCP/IP channels
  • Fixed issue where when capturing a photo in photo badging, the newly captured image would overwrite the existing photo
  • Fixed issue where activation and deactivation dates didn’t always save correctly on a card record

VERSION 7.0.2.11
RELEASE DATE December 20, 2017
MERCURY FIRMWARE 1.2.41 (SSP-D2, SSP-EP, SSP-LX, DController)

New Features

  • Add PIV Enroll to Card

Improvements

  • Improved audit to indicate when someone edits/adds/removes a graphics map
  • Added NSC-100 support to Software House Bridge
  • Added drag/drop support for ASSA doors to Events Grid (filtering)
  • Expanded the number of card formats from 8 to 16
  • Added "Do not tell again" to DNAMessageBox
  • Added button to controller dialog that allows user to "Ping" controller with visually indication of success/failure
  • Added Card + Facility Code option to PCProx
  • Added Card Number to "Access Level Last used" Report

Bug Fixes

  • Fixed issue with Stentofon Events not showing up in Alarm Logging Dialog
  • Fixed cosmetic issue with Icons in the Graphic Map Run-mode context menu
  • Fixed issue with Keycard activation & deactivation dates not updating correctly
  • Fixed an issue with playback of OnSSI archived video
  • Fixed an issue where using the 'Find Cardholder' context item from the Personnel Browser and selecting Company causes an error
  • Fixed - COM Objects not handling the Temporary Override Cancellation properly
  • Fixed - Address column not showing correctly on ASSA Doors (usually shows the DSR)
  • Fixed - Unable to run Trace History on ASSA Door
  • Fixed - Removing multiple cards after sorting the grid on legacy access levels->Assigned to causes application to crash
  • Fixed - Names disappear in the tenant mode after refreshing event grid
  • Fixed - Some Scheduled Custom Reports parameters always default to all
  • Fixed - Access Events set as Alarms are not showing the correct information in the Alarms Screen.
  • Fixed - Macro's Appear to vanish (and sometimes return)
  • Fixed - Deactivating Cards can result in the wrong card on the tree being grayed out.
  • Fixed - Alarm grid sounds not playing the alarm media file selected in the door
  • Fixed - Assa Reports Operator Rights Don't Save
  • Fixed - LX Controller does not connect to NSC100 subcontroller

VERSION 7.0.1.3
RELEASE DATE October 10, 2017
MERCURY FIRMWARE 1.2.41 (SSP-D2, SSP-EP, SSP-LX, DController)

Improvements

  • Added Secure Channel OSDP Support and improved reader status to reflect more OSDP settings
  • Added Who Has Access to Bosch Areas
  • Added support for Alternate Characters in external events (Isonas)
  • Added Progress Bar Status to Bosch User Functions for Larger Databases
  • Filtering Events Grid by dragging Axis Hardware is much faster
  • Reworked the queries for Isonas and Bosch Panel when filtering the Events Grid to improve speed
  • Added latest Isonas Firmware to the install  (RC-03 v62.01, RC-03 (Classic) v30.01, RC-04 v74.06, IP Bridge v11.03)
  • Added more logging for the HTTP Driver based calls
  • Added URL encoding for HTTP driver calls to better support URLs with spaces, etc.

Bug Fixes

  • Fixed issue - Isonas Doors do not reflect Alarm Status consistently with other hardware (will show red when they shouldn’t)
  • Fixed issue - Isonas Status showing incorrect version (‘n/a’) at times when there was actually a valid version in the database
  • Fixed issue - Unable to remove Action from a Macro
  • Fixed issue - Dragging Axis Hardware to the Events Grid results in no results
  • Fixed issue - Dragging Personnel Records to Events Grid results in no results.
  • Fixed issue - Direct Command Editor deletes the wrong command
  • Fixed issue - PTZ Buttons did not handle Full Screen/Double Click properly
  • Fixed issue - Valcam/Twain Interface not working
  • Fixed issue – Using Twain with the external interface option was not working  (Crop window would be blank)
  • Fixed issue – Added Bosch Panel Source Name to events grid
  • Fixed issue – Editing the details of a Host Based Macro that executes HTTP on the driver will cause the HTTP call to be made when you click Ok
  • Fixed issue – Driver based HTTP HBM did not support authentication for GETS
  • Fixed issue – Driver based HTTP HBM did not reset the authentication method between calls
  • Fixed issue -  Bosch Users where the name field was too wide for the underlying table as well as the Bosch Panel
  • Fixed issue -  Issue Code not being positioned correctly on the card holder screen
  • Fixed issue -  Removed SQL related to the DNAInfoCustomColums table that was causing issues
  • Removed the checking for the Offline Duration on Demo Licenses, which is more of an issue now that DNA doesn't check for license updates as often

Isonas Driver

  • Improved mechanism used to transfer events to DNA Driver to better support Alternate character sets (i.e. Accent characters, etc.)
  • Added additional logging around Firmware downloads
  • Fixed issue - TCP/IP connections used for transferring events to the DNA Driver not being released, eventually resulting in failure.
  • Fixed issue - Fixed an issue where it’s possible the driver would download Coldfire Firmware to Classic RC-03 if the firmware version had not been retrieved yet
  • Fixed issue - Isonas Firmware Version not updating in the UI after a firmware upgrade
  • Fixed issue - Fix issue with reporting Device Type for IPBR2/3 (error in manual)

Isonas Log Analyser

  • Fixed issues with not being able to handle encryption messages

VERSION 7.0.0.45
RELEASE DATE September 25, 2017
MERCURY FIRMWARE 1.2.41 (SSP-D2, SSP-EP, SSP-LX, DController)
 
 

New Features

  • Otis elevator integration
  • thyssenkrupp elevator integration
  • ISONAS integration
  • BCG UI upgrade
  • Support for Bosch Mode II
  • Traka integration
  • Ability to export video and send as an attachment via email

Improvements

  • Operator environments can now be sorted in drop down menu when editing
  • Reworked the licensing mechanism to download only when manually initiated from the “help about” screen
  • Added "Company, Department, Title, Site (Personnel), Location” to the list of replaceable parameters
  • Improved Axis download logic that when adding/removing groups with Axis doors it will only download to the affected controllers
  • Adding photos manually is now consistent between badging page and personnel page
  • Refactored the process of adding photos to be consistent across different methodologies
  • IP Address shown on status bar is now correct
  • No prompting for removing a host-based macro
  • Added “Type” column to the Holidays report
  • Removed the triggers on DNAHardwareControl and DNAIssueCommands tables and transferred that logic as a periodic maintenance item in driver
  • Linked devices to event sources in event history report
  • Added support for MT(K)2, MI(K)2 Allegion readers for ONR programming
  • Created a progress dialog to show progress when adding/deleting a GAL to/from personnel
  • Added the ability to assign random unique passcodes to Bosch users when inputting them
  • Added reader override modes (and cancel) to the list of available modes that can be set from graphics maps
  • Changing tenant modes on the server now requires launching the DNA Indexing Utility to ensure indexes are kept in sync
  • Batch print progress messages are now allowed to stay in the grid
  • Added last name/first name to the trace history for Bosch panels
  • DNAHardwareStatus (used for Web/Flex) can now indicate that a door is in an override mode
  • Operators now have the ability to create Bosch panel reports
  • Bosch areas and panels now require a "Browse" button to select home page
  • Enabled web login when driver is off
  • Controllers now report missing panel info
  • Improved functionality for the ISONAS Photo Recall feature
  • Right clicking on NDE door now gives the option for extended modes
  • Site name is now updated in the hardware tree after editing
  • Web service credentials now saves credentials
  • Resolved inconsistencies between online/offline events for Mercury
  • Advanced archiving dialog now shows correct information when run on 32-bit system
  • SIO quantities for multi-site installations are now being calculated correctly
  • Overlapping one-time events now work properly
  • The MPG Arm/Disarm options in host-based macros now work
  • There is now an audit trail when an Axis door is added or edited

Bug Fixes

  • *Escalated Issue* - Fixed issue where door loses ability to unlock
  • Fixed issue where operator was unable to force an Axis download externally (OpenDX)
  • Fixed issue where TCP/IP Event Receiver was not fully handling Axis and ISONAS events as the MSMQ versions were
  • Fixed issue where operator was unable to set use limit on personnel group if legacy access levels aren't assigned to their card
  • Fixed issue where in PhotoID properties, the photo name configuration label would occasionally disappear
  • Fixed issue where if Bosch area assignments were changed via alarm panel setup, the driver may report addresses incorrectly
  • Fixed issue where personnel type was incorrectly handled on Access Level Members dialog
  • Fixed issue where personnel types were shown incorrectly on “Who Has Access”, “No Access”, etc.
  • Fixed issue where dropping Access Level Group on Personnel Group was not obeying Personnel Type Permission
  • Fixed issue when running “Who Has Access” report on ISONAS door it was pulling data from Mercury “Who Has Access” report
  • Fixed issue where removing cards from the interface did not remove them from Axis or ISONAS
  • Fixed issue where editing values stored in DNAEntries the index gets out of sync
  • Fixed issue where “Who Does not Have Access” report did not include group access levels for Mercury doors
  • Fixed issue where running a trace history report on hardware with “Tenants On” will lock up if any of the transactions fail the tenant test
  • Fixed issue where user toolbars are duplicated in v7.x if operator logs out and back in
  • Fixed issue where if the operator doesn’t allow duplicate PIN codes and a duplicate code is entered, you will see the name of whoever has that duplicated code
  • Fixed issue where personnel groups report shortens group name and shows group number in the description
  • Fixed issue where setting maximum floor groups to 256 caused elevator access to stop working
  • Fixed issue where operator yielded inconsistent results when filtering events by Axis/ISONAS/Bosch panels
  • Fixed issue where personnel cards report shows duplicate cards under the same user
  • Fixed issue where bypass tenant section in event history report queries when tenant not “on”
  • Fixed issue where selecting a card format on an Axis controller when adding it would not automatically save
  • Fixed issue where the override mode dialog shows both “Indefinite” and “Minutes” being checked in most cases
  • Fixed issue where right clicking on door (regular Mercury) shows unwanted menu option
  • Fixed issue where removing personnel records was not removing the associated Bosch panel user and was orphaning entries in [Bosch users], etc.
  • Fixed issue where the last badge template printed showed incorrectly in some cases
  • Fixed issue where “Who Does Not Have Access” report was unusable on large databases in some cases
  • Fixed issue where SIO counting mechanism occasionally got out of sync and returned incorrect amounts
  • Removed OverWatch and BACnet options from Web Service Credentials for non LX controllers